Description
The Easy Touch GC is a portable and extremely easy to use instant cholesterol monitoring system designed for both healthcare professionals and for self-testing. CE marked with guaranteed accuracy the Easytouch GC is designed to assist healthcare professionals & patients in the management of the risk of heart disease, diabetes and gout, testing for glucose, total cholesterol and uric acid levels.
Key Features :
- CE marked with proven Accuracy.
- Lowest Cost Worldwide - Both Device and Strips.
- Instant Lipid & Glucose Testing.
- 7 day a week product support & supplies ordering from the Medicaltestcentre
- 2 Year Warranty
What's included in the kit?
- 2 in 1 Meter
- 2 Blood Cholesterol Test Strips
- 10 Blood Glucose Test Strips
- 1 Puncturer / Lancing Device
- 25 Lancets, 1 Check strip
- 2 AAA batteries
- 1 Colour Case Packing
- 1 Carrying Case/Bag
- User's Manual
- 1 Log Book
- 1 Simple Operating Insert
- 1 Warranty Card
Important Information:
Blood specimens containing below cases may give inaccurate glucose results.
- Ascorbic acid (Vitamin C) greater than 150mg/gL
- Amiloride greater then 20 mg/dL
- Acetaminophen greater than 8 mg/dL
- L-Dope greater than 20 mg/dL
- Dopamine greater than 20 mg/dL
- Methyl-Dope greater than 4mg/dL
- Galactose greater than 400 mg/dL
- Urid acid greater greater than 10.5 mg/dL
- Xylose greater than 50 mg/dL
Cholesterol up to 500 mg/dL or triglycerides up to 3000 mg/dL do not significantly affect the glucose results. Grossly lipaemic patients samples have not been tested and are not recommended for testing glucose level with EasyTouch GC System.
Hematocrit (percentage of red blood cells in your blood) below 30% or higher than 55% was found to cause a higher or lower reading, respectively. No significant effect on the reading was found for hematocrits in the blood sample between 30% and 55%.
Blood specimens containing ascorbic acid (Vitamin C) greater than 5mg/dL, uric acid greater than 20mg/dL, aczetaminophen greater than 15mg/dL, L-Dopa greater than 1.25 mg/dL, Dopamine greater than 3 mg/dL, Methyl-Dopa greater than 5 mg/dL, Glibenclimide greater than 10 mg/dL, creatinine greater than 20 mg/dL and Billirubin greater than 20 mg/dL may give inaccurate glucose results.
Blood specimens containing ascorbic acid (Vitamin C) greater than 5mg/dL, acetaminophen greater than 15mg/dL, L-Dopa greater than 1.25 mg/dL, Dopamine greater than 3 mg/dL, Methyl-Dopa greater than 5 mg/dL, Glibenclimide greater than 10 mg/dL, creatinine greater than 20 mg/dL and Billirubin greater than 20 mg/dL may give inaccurate cholesterol results.
Checking your blood glucose level and cholesterol level regularly can help you identify whether your current lifestyle is putting your future health at risk. Diabetes UK estimates there are 7 million pre-diabetic people in the UK and over 1 million UNDIAGNOSED type 2 diabetics. Why is this bad? Unmanaged diabetes can lead to blindness, kidney failure and limb amputation. On average diabetics die 10 years prematurely. The only way you really know if you are at risk of becoming diabetic is to measure your blood glucose level. High total cholesterol in your blood is a risk factor associated with heart attacks, angina, strokes and much more. HEART UK estimates that 6 in every 10 of us have a raised cholesterol level. There are often no symptoms of high cholesterol and so the only way you know you have it is if you get it measured. Thankfully, prediabetes and high cholesterol can be reversed and help prevent future illness by adopting small lifestyle changes, such as eating healthier and exercising. This dual-function single monitor offers an easy way to keep a check of your glucose and total cholesterol levels. Simple to use, this small unit comes in its own protective carry case which can also house your lancing device and test strip containers. You can trust this device to be accurate time and time again. The test strips for this device are some of the cheapest available on the market providing you with an affordable way to keep a check on two of your Lifestyle Markers (Glucose and Total Cholesterol).
The Easytouch GC is fully CE marked under EC directive 98/79/EC Annex IV, Article 3 for home & professional use. CE registration number HL 600202810001. Furthermore official testing shows Easytouch GC to have an accuracy level equal to other leading brands.
Cholesterol & glucose screening has never been so accessible. Our economically priced test strips make the Easytouch GC testing system the most competitive device of its type worldwide. Accurate enough for the professional yet easy to use and affordable enough for the patient.